Vis enkel innførsel

dc.contributor.authorShalfawi, Shaher
dc.contributor.authorEnoksen, Eystein
dc.contributor.authorTønnessen, Espen
dc.date.accessioned2012-10-23T10:30:58Z
dc.date.available2012-10-23T10:30:58Z
dc.date.issued2012-06
dc.identifierSeksjon for fysisk prestasjonsevne /Department of physical performance
dc.identifier.citationInternational Journal of Fundamental and Applied Kinesiology. 2012, 44(1), 24-30no_NO
dc.identifier.issn1331-1441
dc.identifier.urihttp://hdl.handle.net/11250/170968
dc.description.abstractThe aim of the present study was to assess the test-retest reliability of the Brower Speed Trap II running speed timing system. The test-retest reliability of the system was assessed by testing 52 physical education students aged (±SD) 21.4 (±8.9) years. All participants were tested on 30-m sprint with 10-m, 20-m and 30-m split times. All measurements were obtained on two subsequent days. The results from this investigation indicate that the variations in the students’ performance between test day one and test day two was small and the intra-class correlation indicates a high repeatability. In the examination of the system reliability, the system did not show any marked systematic bias (p<.05) assessed by the paired sample t-test. However, the systematic bias and the random variation found indicate that the Brower Speed Trap II running speed timing system was a reliable testing instrument to be used in testing physical education students, and a useful instrument for measuring running speed. However, in future studies it would be interesting to examine if the system were able to monitor the small changes in running speed that could result from increasing the training of an already elite athlete. Furthermore, we concluded that if comparison of overall values of running speed is intended, it is advisable to use the same testing system, because different systems give different results based on the errors associated with it.no_NO
dc.language.isoengno_NO
dc.publisherFaculty of Physical Education, Kroatiano_NO
dc.subjectrunning speedno_NO
dc.subjectheteroscedasticno_NO
dc.subjectlimits of agreementno_NO
dc.titleAssessing test-retest reliability of the portable Brower speed trap II testing systemno_NO
dc.typeJournal articleno_NO
dc.typePeer reviewedno_NO
dc.subject.nsiVDP::Medical disciplines: 700::Sports medicine: 850::Movement instruction: 852no_NO
dc.source.pagenumber24-30no_NO
dc.source.volume44no_NO
dc.source.journalInternational Journal of Fundamental and Applied Kinesiologyno_NO
dc.source.issue1no_NO


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel