Vis enkel innførsel

dc.contributor.authorWedege, Pia
dc.contributor.authorSteffen, Kathrin
dc.contributor.authorStrøm, Vegard
dc.contributor.authorOpheim, Arve Isak
dc.date.accessioned2017-10-10T09:14:16Z
dc.date.available2017-10-10T09:14:16Z
dc.date.issued2017-09-14
dc.identifier.citationJournal of Rehabilitation and Assistive Technologies Engineering. 2017, 4, 1-10nb_NO
dc.identifier.urihttp://hdl.handle.net/11250/2459369
dc.description.abstractObjectives: Three-dimensional gait analysis has been recommended as part of standardized gait assessment in people with spinal cord injury. The aim was to investigate inter- and intra-session reliabilities of gait kinematics in people with spinal cord injury. Methods: Fifteen adults with spinal cord injury performed two test sessions on separate days. Six infrared cameras, 16 reflective markers and the Plug-in gait model were used. For each subject, five gait trials from both sessions were included. The Gait Profile Score and the Gait Variable Score were used as kinematic outcome measures. Reliability was assessed with intraclass correlation coefficient, standard error of measurement, minimal detectable change, and Bland–Altman plots. Results: Inter-session intraclass correlation coefficient for all variables was >0.82 and standard error of measurement <1.8°, except for hip rotation. Intra-session reliability was found to be high (≥0.78) and slightly better than that for inter-session. Minimal detectable change for all variables was <4.7°, except for hip rotation. Conclusions: The high inter- and intra-session reliabilities indicate small intrinsic variation of gait. Thus, three-dimensional gait analysis seems to be a reliable tool to evaluate kinematic gait in adults with spinal cord injury, but caution is warranted especially for hip rotation evaluation.nb_NO
dc.language.isoengnb_NO
dc.publisherSagenb_NO
dc.subjectspinal cord injurynb_NO
dc.subjectwalkingnb_NO
dc.subjectthree-dimensional gait analysisnb_NO
dc.subjectreliabilitynb_NO
dc.subjectintrinsic variationnb_NO
dc.titleReliability of three-dimensional kinematic gait data in adults with spinal cord injurynb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.source.journalJournal of Rehabilitation and Assistive Technologies Engineeringnb_NO
dc.identifier.doi10.1177/2055668317729992
dc.description.localcodeSeksjon for idrettsmedisinske fag / Department of Sports Medicinenb_NO


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel